Description
Specifications:
Electrical | |
REGULATORY COMPLIANCE | RoHS , CE 0682,ATEX DIRECTIVE 94/9EC,GROUP I,M1,ia. |
FREQUENCY RANGE | 865 – 956 MHz |
GAIN | 7.0 dBic (min) , 8.5 dBic (max) @ 865-870 MHz
7.0 dBic (min) , 9.5 dBic (max) @ 902-928 MHz 7.0dBic (min) , 9.0 dBic (max) @ 950-956 MHz |
VSWR | 1.2:1 (typ) 1.5 : 1(max) |
POLARIZATION | RHCP |
3dB ELEVATION BEAMWIDTH | 65° (typ) |
3dB AZIMUTH BEAMWIDTH | 65° (typ) |
F/B RATIO | -18 dB (max) |
POWER | 6W (max) |
INPUT IMPEDANCE | 50 (ohm) |
AXIAL RATIO | 865-870 MHz @ 2.5 dB (max)
902-928 MHz @ 1dB(typ) 1.5 dB (max) 950-956 MHz @ 3.0 dB (max) |
LIGHTNING PROTECTION | DC Grounded |
Mechanical | |
DIMENSIONS (LxWxD) | 305 x 305 x 22.5 mm (max) |
CONNECTOR | TNC JACK Reveres Polarity |
WEIGHT | 1.6 kg (max) |
RADOME MATERIAL | PC Conductive |
OUTLINE DRAWING | RD44186400M |
Environmental | ||||
Test | Standard | Duration | Temperature | Notes |
LOW TEMPERATURE | IEC 68-2-1 | 72 h | -55°C | |
HIGH TEMPERATURE | IEC 68-2-2 | 72 h | +71°C | |
TEMP. CYCLING | IEC 68-2-14 | 1 h | -45°C +70°C | 3 Cycles |
VIBRATION | IEC 60721-3-4 | 30 min/axis | Random4M5 | |
SHOCK MECHANICAL | IEC 60721-3-4 | 4M5
|
||
HUMIDITY | ETSI EN300-2-4 T4.1E | 144 h | 95%
|
|
WATER TIGHTNESS | IEC 60529 | IP67 (*please see comment below)
|
||
SOLAR RADIATION | ASTM G53 | 1000h | ||
FLAMMABILITY | UL 94 | Class VO | ||
SALT SPRAY | IEC 68-2-11 Ka | 168h | ||
ICE AND SNOW | 25mm Radial | |||
WIND SPEED SURVIVAL OPERATION | 220 Km/h
160 Km/h |
|||
WIND LOAD (SURVIVAL)
FRONT THRUST SIDE THRUST |
26.6 kg
2.0 kg |
|||
THERMAL ENDURANCE TO HEAT | IEC 60079-0
Section 26.8
|
4 weeks | 80°c | |
THERMAL ENDURANCE TO COLD | IEC 60079-0
Section 26.9 |
24h | -60°c | |
RESISTANCE TO OILS, GREASE AND HYDRAULIC LIQUIDS | IEC 60079-0
Section 26.11 |
|||
RESISTANCE TO LIGHT | IEC 60079-0
Section 26.10.1 |
|||
EARTH CONTINUTY | IEC 60079-0
Section 26.12 |
|||
SURFACE RESISTANCE-
CHARGING TESTS |
IEC 60079-0
Section 26.13
Section 26.14 |